Input
|
- Jumper selectable input
voltage range:
|
90 – 135 Vac
190Vac – 264Vac |
|
1 mA RMS max. |
|
|
> 80% |
Output
|
|
|
+5,1Vdc (aux)
+24Vdc (main)
+30Vdc (main) |
|
|
70W |
|
|
250W (10 sec.) |
|
|
360W (3 sec.) |
|
Microprocessor controlled protections |
|
- Under/overvoltage protection
- Overload / Short circuit protection
- Time related output power / current protection
- Automatic switch-off
- Reset by removing the AC-input
- The main converter has the ability to foldback at very high load conditions without affecting the performance of the 5V auxiliary output
|
|
| Safety & EMC |
|
- EN 60950 Class I
- UL 60950 Class I
- EN 60335 Class I
- EN 50081-1
- EN 55014
- EN 50082-1
- EN 55104
- EN 61000-4-2,3,4,5,6,11
- EN 61000-3-3
- Class 2 LPS
|
|
|
|
Certificates |
|
|
|
| Cooling |
|
|
|
Mechanical construction |
|
- Enclosed housing: custom made anti-fluid drip housing
|
|
Connections
|
|
|
JST 5 pins connector |
|
|
JST 2 pins connector |
|
Dimensions
|
|
|
180 × 94 × 55 mm |
| 7,1 × 3,7 × 2,2 inch |
|
|
0,7 KG |
|
|